F-1000 Cartridge (included with this system) Chemical & Mechanical Reduction Filter Specifications:
This cartridge provides mechanical and chemical reduction of chlorine taste & odor and particulate class III.
Filter Capacity:
500 gallons, depending on local water conditions. Note that while the testing was performed under
standa
rd laboratory conditions, actual performance may vary. Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection befo
re or after the system. For cold water use only.
Systems must be
installed and operated in accor
dance with the Manufacturer’s recommended procedures and guidelines. See warranty
ca
rd for warranty. For service and parts, contact your local dealer or InSinkErator
®
directly at 1-800-558-5700.
A
pplication guidelines/Water Supply Parameters for NSF Testing: Service flow of 0.75 gpm, community or
private well water suppl
y, water pressure of 20-120 psi (138-827 kPa), water temperature of 33˚F–100˚
Nominal
Particulate Class III,
5 µm to <15 µm
270,000 pts/mL
2.1 mg/L 2.0 mg/L ± 10%
At least 10,000
particles/mL
82 pts/mL 99.9%
85%
0.06 mg/L 97.0%
50% J-00082587
J-00119308
F Except as
noted, all testing performed at pH = 7.5
± 0.5, Flow: 0.75 gpm, Pressure: 60 psi, Temp: 20˚± 3˚C.
Contact an authorized InSinkErator service agent for repairs or replacement components. Replacement filters
F-1000 and F-2000 can be ordered by calling 800-558-5700, visiting shop.insinkerator.com, or by contacting
an authorized InSinkErator reseller.
Refer to the Performance Data Sheet for InSinkErator Filter System Model F-2000S
Replacement Cartridge: F-2000
Pressure: 30-120 (207-827 kPa) psi
Temperature: 33
º
F - 100
º
F
Flow Rate: 0.75 gpm
Capacity: 500 gallons
Tested & Certified by NSF International against NSF/ANSI Standard 42 in the following
InSinkErator Systems Only: GN1100, HC1100, GN2200, HC2200, GN2215, HC2215,
H3300 or HC3300 for the reduction of claims specified on the Performance Data Sheet.
For systems using two handle HC model faucets, operate only one handle at a time.
Turn off water supply before starting.
Installation must comply with all state and local laws and regulations.
Property Damage: Do not extend the lines farther
than the 16" provided. Ensure tube(s) and “Y
connnector are securely fit.
Personal Injury: Do not locate filter above an
outlet or other electrical device. Install head and
bracket so that connections require no stretching,
kinking or pinching of tubing.
It is normal for approximately 2 oz. of water
to discharge when filter is removed.
Property Damage: Tube runs need to form to the
cabinet’s contours to allow storage space with no
sharp bends. Tubes need clean, perpendicular,
burr-free cuts to ensure a true fit.
a
c
From water
supply line
To dispenser
d
INSTALLING FILTRATION SYSTEM
b
From water
supply line
To dispenser
Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or
burns. Use care when operating this appliance.
Property Damage: Join remaining tube
to cold water supply only.
Turn on the water supply.
Depress the dispenser’s HOT handle
and hold it until water flows from the
spout (approximately 1 to 2 minutes).
For the F-1000S and F-1000, flush
2.25 gallons through filter before use
(approximately 3 minutes). For the
F-2000S and F-2000, flush 3 gallons
through filter before use (approximately
4 minutes).
Check all connections to ensure they
are tight and that there are no leaks.
Install a T-fitting (not included)
onto the cold water supply line.
Install dedicated water control valve
with 1/4" compression fitting.
At the end of the white 1/4" tube
from the filter or quick-connector,
slide the supplied brass nut and
ferrule over the tube and then push
in the brass tube insert.
Insert the white 1/4" tube into the 1/4"
compression fitting and tighten.
FINAL WATER CONNECTION
TURN ON WATER & CONNECT POWER
Brass Nut
Ferrule
Brass
Insert
1/4"
Plastic
Tube
3
2
1
5
4
a
a
From filter or
water supply line
Plug
From filter or
water supply line
HC1100, HC2200,
HC2215
GN1100, GN2200, GN2215,
HC3300, H3300
Determine length of tubing required,
then cut to length making sure the cut
is perpendicular and burr-free.
Insert a white 1/4" tube into inlet side
of filter head until it stops. Press in
again to ensure a secure fit.
Insert the other white 1/4" tube into
outlet side of filter head until it stops.
Press in again to ensure a secure fit.
Separate cartridge from filter head.
Mark hole locations for filter head
and bracket in a spot that allows
for filter replacement.
Drill 1/8" starter holes and attach bracket
to wall with wood screws, turning until snug.
Insert cartridge into filter head. Top
surface of cartridge will become flush with
bottom of filter head when fully engaged.
Connect remaining white 1/4" tube to
incoming water supply line.
Insert the copper tubes(s) from the
dispenser into “Y” quick-connector
using the plug for hot-only models.
Connect the white 1/4" tube from
the right outlet on the filter head into
the quick-connect fitting until it stops.
Press in again to ensure a secure fit.
To remove tube(s) or plug from quick-connector,
depress the release ring and gently pull away.
Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not supplied) for installation into drywall.